Quality & Compliance
How we keep every API and food-grade raw material we supply compliant, traceable and fit for manufacturing.
QUALITY ASSURANCE & QUALITY CONTROL POLICY
Obimed Pharmaceuticals Limited
Control Element
Reference Information
Document Control Number
OPL/QA/SOP/001
Effective Date
October 2026
Review Date
October 2028
Entity
Obimed Pharmaceuticals Limited ("Obimed")
Scope
Raw Material Sourcing, Active Pharmaceutical Ingredients (APIs), Excipients, Food-Grade Additives, Storage, and B2B Distribution
1. Policy Statement & Purpose
Obimed Pharmaceuticals Limited is committed to delivering Active Pharmaceutical Ingredients (APIs), pharmaceutical excipients, and industrial food additives that consistently comply with international pharmacopeial standards (USP, BP, EP), local regulatory requirements (NAFDAC, PCN), and client specifications.
This Quality Assurance Policy establishes strict, audit-ready operational frameworks for vendor qualification, batch traceability, sampling, storage control, and Certificate of Analysis (COA) verification across all raw material procurement and supply chain cycles.
2. Vendor Qualification & Supplier Auditing
To guarantee supply integrity at the source, all international and local manufacturers supplying Obimed must undergo a mandatory Vendor Qualification Process prior to onboarding.
- Audit Requirements: Suppliers must provide proof of Good Manufacturing Practice (GMP) certification issued by a recognized regulatory authority (e.g., US FDA, EMA, WHO-GMP, or equivalent local regulatory authority).
- Documentary Due Diligence: Every vendor onboarding file must contain:
- Manufacturer GMP and ISO certificates.
- Site Master File (SMF) summary or Drug Master File (DMF) open parts where applicable.
- Product Specification Sheets and Material Safety Data Sheets (MSDS).
- Historical Certificate of Analysis (COA) batch records.
- Periodic Re-Evaluation: Approved Suppliers are re-evaluated annually based on batch consistency, delivery compliance, COA accuracy, and audit track record.
3. Receiving, Inbound Inspection & Quarantine Protocol
All incoming consignments of raw materials (APIs, excipients, and food-grade chemicals) arriving at Obimed’s warehouses or client fulfillment centers must undergo strict inbound inspection.
Inbound Operational Workflow
- Inbound Shipment Arrival & Physical Inspection: Check seal integrity, labeling, container integrity, and batch match.
- Quarantine Area Placement: Upon offloading, materials are immediately placed in a designated, physically segregated Quarantine Area under "HOLD" status (Yellow Flag / Status Tag).
- QC Sampling & Testing: Quality Control (QC) officers perform sampling using representative statistical sampling techniques (e.g., $n = 1 + \sqrt{N}$ sampling plan) in accordance with pharmacopeial guidelines.
- COA Reconciliation: The manufacturer's batch Certificate of Analysis (COA) is cross-verified parameter-by-parameter against Obimed's internal acceptance standards and client specifications.
- Disposition: Approved materials receive a Green Tag for inventory release. Rejected materials receive a Red Tag and are moved to isolated quarantine.
4. Analytical Verification & Testing Standards
- In-House & Retain Sampling: Retain samples from every imported batch are securely archived in the QA Retain Sample Vault for a minimum of 12 months beyond the product expiration date.
- Third-Party Confirmatory Testing: For high-volume APIs and sensitive excipients, Obimed engages NAFDAC-accredited independent analytical testing laboratories to verify:
- Identification & Assay Percentage (e.g., HPLC / Titration).
- Impurity Profile & Residual Solvents.
- Microbial Limit Testing (MLT) for food-grade and oral formulation raw materials.
- Physical Properties: Particle size distribution, loss on drying (LOD), bulk/tapped density, and solubility.
5. Storage, Climate Control & Distribution QA
Obimed maintains warehouse conditions designed to protect chemical stability and prevent degradation or cross-contamination.
Storage Parameters
Parameter
Specification & Operational Standard
Monitoring Protocol
Ambient Storage
Controlled 15°C to 25°C (30°C max excursions)
Continuous digital logging & 2x daily manual audits
Cold Chain
2°C to 8°C refrigerated storage
Continuous automated alarm systems
Relative Humidity
Below 60% RH
Daily verification via calibrated hygrometer
Segregation
Physical separation by shipment intake
Separate area designation for Food-Grade vs. Pharma Grade
Distribution Framework
- FEFO System: Materials are dispatched using a strict First Expired, First Out (FEFO) inventory management system to prevent shelf-life erosion.
- Dispatch Documentation: Every outgoing client shipment is dispatched with an official, signed Obimed Quality Delivery Pack, containing:
- Batch-specific Certificate of Analysis (COA).
- Material Safety Data Sheet (MSDS).
- Quality Release Certificate signed by the Designated Qualified Person / QA Lead.
6. Out-of-Specification (OOS) & Customer Complaints Protocol
- Out-of-Specification (OOS) Handling: Any batch failing analytical testing or visual inspection is immediately moved to the physically locked Rejected Materials Storage (tagged with Red Notice Signs). An OOS Investigation Report is opened within 24 hours to identify root causes.
- Customer QA Complaints: Client complaints regarding raw material performance, particle size discrepancies, or packaging defects must be logged within 5 business days of delivery. Obimed QA initiates a joint investigation within 48 hours. If non-conformance is validated, Obimed coordinates immediate product recall, quarantine of affected lots, and replacement batch release at no extra cost to the client.
7. Change Control, Traceability & Audit Readiness
- Batch Traceability: Obimed maintains complete batch traceability logs from port of entry to client manufacturing facility, ensuring any lot can be pinpointed and recalled within 24 hours.
- Change Control: Any change in raw material manufacturing site, synthetic route, or packaging specification requires formal notification to downstream manufacturing clients prior to dispatch.
- Annual QA Review: All QA/QC protocols are subjected to an annual management audit to maintain alignment with evolving NAFDAC guidelines, PCN regulations, and international standards.
Document Approval
Role
Entity / Department
Drafted By
Legal & Quality Assurance Compliance Team
Approved By
Management, Obimed Pharmaceuticals Limited
Distribution List
Quality Control Unit, Operations, Warehouse Logistics, and B2B Sales Desk